Bypassing a Zone

Bypassing a zone allows you to ignore (deactivate) specified zones the next time the system is armed. For example, you may wish to bypass certain zones when workers are renovating part of your home. Once the system is disarmed, the bypass entries are erased. When zones are bypassed, the [BYP] key will illuminate. Zone bypassing can also be activated by using One-Touch Bypass Programming. If One-Touch Bypass Programming is enabled, press the [BYP] key for three seconds to enter bypass programming. To remove the Bypass feature from a zone, in step 3 enter the zone number again or press [CLEAR] to erase all current entries. Press [CLEAR] + [ENTER] to delete bypassed zones.

How do I bypass zones?

  1. Press the [BYP] key.
  2. Enter [USER CODE].
    The [
    BYP] key will flash. Press [ENTER] to bypass all open zones or go to step 3.
  3. Illuminate the number(s) corresponding to the zone(s) you want to bypass by entering the zone number.
    Solid on = Zone open, Flash = Zone bypass, Off = Zone closed, not bypassed.
  4. Press the [ENTER] key to save and exit. Press [CLEAR] twice to exit without saving.

 

Bypass Recall Feature

After disarming the system, bypass entries are erased. The Bypass Recall feature reinstates the previous bypass entries saved in memory. This eliminates the need to manually re-program the bypass entries every time you arm your system.


How do I recall bypass entries?

  1. Press the [BYP] key.
  2. Enter your [USER CODE].
  3. Press the [BYP] key.
  4. Press the [ENTER] key.


    • Related Articles

    • How to Arm & Disarm Your Paradox Magellan/Spectra Alarm

      In this article, we will go over the different methods for arming and disarming your Paradox Magellan/Spectra alarm system, including Regular arming, Sleep arming, and Stay arming. We will also provide instructions on how to disarm an armed system ...
    • Paradox Fault Analysis Mode

      This article does not apply to systems with touchscreen keypads It is important to be aware of the various trouble conditions that can be reported to your monitoring station. When a trouble condition occurs, the TBL key or light on your keypad will ...
    • Paradox Magellan - Other Alarm Types

      This article does not apply to systems with touchscreen keypads Your Paradox system has different types of alarms available other than just intruder alarms. Fire Alarms Upon a fire alarm, the bell/siren will emit three “squawks” at 2 second intervals ...
    • Modifying User Codes on a Paradox Magellan/Spectra System with a TM50/70 Touch Screen Keypad

      This guide is applicable for all Magellan and Spectra SP Systems equipped with TM50/70 touch screen keypads. For systems fitted with a push button keypad, refer to this guide: Modifying User Codes on a Paradox Magellan/Spectra System with a Push ...
    • Paradox StayD

      StayD Overview The StayD needs to be enabled by your installer before it can function. Contact us on 02 6332 9333 if you want to enable StayD The revolutionary StayD feature represents a completely reversed philosophy compared to all other security ...