Bosch 6000 Alarm System Basic Functions Guide

Bosch 6000 Alarm System Basic Functions Guide

In this guide, you will find instructions on how to arm and disarm the panel, trigger duress or silent alarms, bypass zones, set chime mode, and reset smoke detectors. Follow the steps provided to efficiently use and maintain your Bosch 6000 Alarm System.

Arming the Panel

  1. Enter your PIN code on the keypad, then press the "ON" key.
  2. If your PIN is valid and all zones are normal, the exit delay timer will start. You should leave the premises at this time.
  3. If your control panel detects a fault in a zone, you will need to resolve the issue or bypass the zone before arming the panel.
During the exit delay period, you can cancel the arming process by entering your PIN followed by the "OFF" key.

Disarming the Panel

  1. Enter your PIN code on the keypad, then press the "OFF" key.

Duress or Silent Alarms

To trigger a duress alarm, enter your normal PIN code followed by the last two digits of your PIN code and either the "ON" or "OFF" key.
Example: If your PIN code is 2580, to send a duress report when the area is off, enter [2] + [5] + [8] + [0] + [8] + [0] + [OK] or [ON].
If your PIN code is 2580, to send a duress report when the area is on, enter [2] + [5] + [8] + [0] + [8] + [0] + [OFF].

Bypassing Zones

  1. Enter [MENU] + [3] + [0] + [2] on the keypad.
  2. A list of zones that can be bypassed will appear on the keypad. A tick next to the zone name indicates that it is already bypassed.
  3. Use the up and down arrow keys to select the zone you want to bypass, then press [OK]. Alternatively, you can enter the zone number and press [OK].
  4. Press "ON" or "OFF" to toggle the zone between bypassed and un-bypassed.
  5. Press [OK] to save and exit, or press [MENU] to exit without saving.
Repeat these steps to bypass or un-bypass additional zones.

Chime Mode

  1. Enter programming mode by entering your PIN code followed by [MENU] on the keypad.
  2. Enter [MENU] + [3] + [0] + [3] on the keypad.
  3. A list of areas will appear on the keypad. Use the up and down keys to select the area you want to program chime mode for, then press [OK].
  4. The keypad will display a list of all zones that can be set to chime mode.
  5. Use the up and down keys to select the zone you want to set for chime mode, then press [OK]. Alternatively, you can enter the zone number and press [OK].
  6. Press "ON" or "OFF" to toggle the zone between chime mode on and off.
  7. Press [OK] to save and exit, or press [MENU] to exit without saving.

Resetting a Smoke Detector

  1. Enter [MENU] + [3] + [0] + [5] on the keypad.
  2. A list of areas will appear on the keypad. Use the up and down keys to select the area where the smoke detectors are located, then press [OK]. Alternatively, you can enter the area number and press [OK].
  3. The keypad will automatically return to the menu once all smoke detectors in the selected area have been reset.

    • Related Articles

    • Testing Your Bosch Solutions 16 Alarm System

      It is important to regularly test your Bosch Solutions 16 alarm system to ensure that it is functioning properly and meets all necessary compliance standards. Insurance companies may also require annual servicing. System Tests To test the different ...
    • Bosch Solutions 16 Alarm Systems - Adding and Deleting User Codes

      This article is for alarms with these type of keypads This guide is for users familiar with Bosch Alarm Systems. It covers the process of adding and deleting user codes for the system. It is important to note that only the Master Code holder can add ...
    • How to Fix a Bosch Solutions 16 Alarm System That Won't Arm

      If you are having trouble arming your Bosch Solutions 16 alarm system, there are a few steps you can try before contacting tech support. Bypassing Zones Sometimes it is necessary to bypass certain zones of your alarm system when it is being armed. ...
    • Additonal Functions of Hills/DAS/NX Reliance Alarm Systems

      Reliance alarms are fitted with a host of additional features. Each feature is explained here, including the instructions for activation. Door Chime Chime mode provides an audio warning when a protected area is entered. The door chime is turned on or ...
    • Arm & Disarm - Bosch/Solutions 16 Alarm

      Disarming the Panel Enter a valid user code. Press the Hash [#] button. The keypad will beep 2 times when the panel is disarmed. Arming the Panel Enter valid user code. Press the Hash [#] button to arm. Two beeps will be heard. The AWAY LED/LCD ...